Appendix A: Serial Commands 229
MACRO – Macro Execution/Reporting
This command executes a specified macro or reports the last macro executed.
Command Form: DEVICE MACRO [Value]
Argument Type Size Values Units
Value Channel 4 See 14 (C) in Groups and Channels
(Null to query last macro ran in text)
NOTE
: The response will indicate successful execution of the macro, but it does not guarantee
that each command in the macro was executed.
MANUFACTURER – Manufacturer Identification Label
This command selects/reports the model identification label of the specified channel.
Command Form: DEVICE MANUFACTURER <Channel> <Group> <Reserved>[Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 1, 2, 3, 7
(I, O, M, L)
Reserved Unsigned
Integer
2 0
Label
String 16 1-16 characters
CLEAR = clear the label
(Null to query in text)
dB
MODEL – Model Identification Label
This command selects/reports the model identification label of the specified channel.
Command Form: DEVICE MODEL <Channel> <Group> <Reserved>[Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 1, 2, 3, 7
(I, O, M, L)
Reserved Unsigned
Integer
2 0
Label
String 16 1-16 characters
CLEAR = clear the label
(Null to query in text)
dB
MAX – Maximum Gain Setting
This command changes or reports back the maximum gain setting for an input, output or assignable processing
block.
Command Form: DEVICE MAX <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 1, 2, 3, 5, 7, 12, 16, 17 (I, O, M, P, L, F, T, R)
Value Signed Float 2 -65.00 – 20.00
(Null to query in text)
dB