Appendix A: Serial Commands 235
PP – Phantom Power
This command selects/reports the setting of phantom power.
Command Form: DEVICE PP <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3 (M)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
PRESET – Preset Execution/Reporting
This command selects/reports the state of a preset.
Command Form: DEVICE PRESET <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 0 (Binary)/Null (Text) = Query Last Preset Ran
See Groups and Channels
Group Group 1 13 (S)
Value Unsigned Integer 2 0 = Set preset state to off
1 = Set state to on and execute if not already on
2 = Execute and return state to off
(Null to query current state in text)
PRGSTRING – Program String
This command sets/reports a programmed string.
COMMAND FORM: DEVICE PRGSTRING <ID> [Value]
Argument Type Size Values Units
ID Unsigned Integer 4 0 – 7
Value String 80 CLEAR = Clear current value
1 – 80 Chars
(Null to query in text)
Special Characters:
\a = alert
\b = backspace
\f = form feed
\n = new line
\r = carriage return
\t = horizontal tab
\v = vertical tab
\\ = backslash
PTTTHRESHOLD – Push to Talk Threshold
This command selects/reports the setting of the push to talk threshold for a microphone.
Command Form: DEVICE PTTTHRESHOLD <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3 (M)
Value Float 2 -100 to 0
(Null to query in text)
dB