ClearOne CONVERGE USB Specifications Page 229

  • Download
  • Add to my manuals
  • Print
  • Page
    / 264
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 228
Technical Services: 800-283-5936 225
Cross point 1 High
(Gated Mics & all other inputs)
Hexadecimal 4 Bit mask of columns 31 - max
Cross point 1 Low
(Gated Mics & all other inputs)
Hexadecimal 4 Bit mask of columns 0 – 31
Cross point 2 High
(Non Gated Mics)
Hexadecimal 4 Bit mask of columns 31 - max
Cross point 2 Low
(Non Gated Mics)
Hexadecimal 4 Bit mask of columns 0 – 31
Cross point 3 High
(Pre-AEC Mics)
Hexadecimal 4 Bit mask of columns 31 - max
Cross point 3 Low
(Pre-AEC Mics)
Hexadecimal 4 Bit mask of columns 0 – 31
Also, a microphone cannot be routed in more than one way to the same output. So the three cross point words
anded together should equal zero.
MTRXCLEAR – CLEAR MATRIX
Clears the ENTIRE matrix for the unit. There is no query for this command.
Command Form: DEVICE MTRXCLEAR
Argument Details
None
MTRXLVL - MATRIX ATTENUATION ADJUST
This command selects/reports the matrix level at the cross point.
Command Form:
DEVICE MTRXLVL <Src. Ch.> <Src. Gp.> <Dest. Ch.> <Dest. Gp.> [Value] [A/R]
Argument Details
Name Type Size Values Units
Source Channel Channel 1 See Group and Channels
Source Group Group 1 1, 3, 5, 6, 7, 12, 17
(I, M, P, E, L, F, R)
Destination Channel Channel 1 See Group and Channels
Destination Group Group 1 2, 5, 6, 12, 16,
(O, P, E, F, T,)
Value Signed Float 4 -99.00 – 99.00 **
(Null to query in text)
DB
Absol / Rel 0 A = Absolute
R = Relative
Null = Relative
** Note: Values indicate entry range only. Actual internal range of the matrix attenuation is from –60 to 12 and
absolute values will be limited to the internal gain range.
MUTE - MUTE
This command selects/reports the setting of mute on a channel.
Command Form: DEVICE MUTE <Channel> <Group> [Value]
Argument Details
Name Type Size Values
Channel Channel 1 See Group and Channels
Group Group 1 1, 2, 3, 5, 7, 12, 16, 17 (I, O, M, P, L, F, T, R)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
NAME – NAME
This command sets/reports the name of the unit which is also used for its Ethernet name.
Command Form: DEVICE NAME [Value]
Page view 228