257
SERIAL COMMANDS
Serial commands are shown in bold, followed by the command form and argument details.
AA – Auto Answer Enable / Disable
This command selects/reports the setting of auto answer.
Command Form: DEVICE AA <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17 (R) -
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
AAMB – Adaptive Ambient Mode
This command selects/reports the setting of adaptive ambient.
Command Form: DEVICE AAMB <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3 (M) -
Value Unsigned Integer 2 0 = Off
1 = On
2 = toggle
(Null to query in text)
-
AARINGS – Number of Rings to Auto Answer On
This command selects/reports the setting of the number of rings to auto answer.
Command Form: DEVICE AARINGS <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17 (R) -
Value Unsigned Integer 2 2 - 4
(Null to query in text)
-
ACONN – Audible Connect / Disconnect Indication
This command selects/reports the status of the audible connect / disconnect indication.
Command Form: DEVICE ACONN <Channel> [Value].
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17 (R) -
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-