CONNECT AVB UNIT PROPERTIES
The next two figures show the Unit Properties tabs for the CONNECT AVB bridge.
On the General tab, set the Device ID (DID) to match that of the rotary selection switch of the CONNECT AVB
device.
The AVB tab is used to perform basic configuration setup of the AVB endpoint.
Reset
Forces initialization of audio streaming after Talker, Listener and TX changes are made.
Talker and Listener Stream ID’s
AVB endpoints are able to pass streams between each other. The Talker sends the stream and the Listener
receives the stream. On a network, each stream has a unique 64 bit (hex) ID. A Talker must be assigned a unique
ID. For the Listener to receive the stream, it must be assigned the same ID as the desired Talker. The CONVERGE
AVB is both a Talker and a Listener
Number of Audio Channels per AVB Talker
When the Converge AVB is a Talker it can be set to use 2, 4, 6, or 8 audio channels. On the E-bus connected
CONVERGE Pro, the audio channels start with the S Bus input.
Number of Audio Channels per AVB Listener
When the Converge AVB is a Listener it can receive 2, 4, 6, or 8 audio channels. On the E-bus connected
CONVERGE Pro the audio channels start with the S Bus output.