290
MLINE – Mic / Line Coarse Gain Setting
This command selects/reports the setting of coarse gain.
Command Form: DEVICE MLINE <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3 (M) -
Value Unsigned Integer 2 0 = 0 dB
7 = 7 dB
14 = 14 dB
21 = 21 dB
28 = 28 dB
35 = 35 dB
41 = 41 dB
50 = 50 dB
56 = 56 dB
(Null to query in text)
(No other values are valid and accepted)
-
MMAX – Maximum Number of Microphones
This command selects/reports the maximum number of microphones for a Gating Group.
Command Form: DEVICE MMAX <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 4 (G) -
Value Unsigned Integer 2 0 = Unlimited
1 - 8 = Maximum # of Mics
(Null to query in text)
-
MODEL – Model Identification Label
This command selects/reports the model identification label of the specified channel.
Command Form: DEVICE MODEL <Channel> <Group> <Reserved>[Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 1, 2, 3, 7
(I, O, M, L, D)
-
Reserved Unsigned
Integer
2 0
-
Label String 16 1-16 characters
CLEAR = clear the label
(Null to query in text)