Clearone Converge Pro User Manual Page 308

  • Download
  • Add to my manuals
  • Print
  • Page
    / 380
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 307
303
RINGMOD – Ring Cadence Mode
This command sets the ring cadence to either standard mode or custom mode. The cadence can be set using the
RINGON and RINGOFF commands. The country code should be set first using the COUNTRY command.
Command Form: DEVICE RINGMOD <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17 (R) -
Value Unsigned Short 2 0 = Standard
1 = Custom
(Null to query in text)
-
RINGOFF – Ring Cadence Off Time
This command sets the ring cadence off time. The country code should be set first using the COUNTRY
command.
Command Form: DEVICE RINGOFF <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17 (R) -
Value Unsigned Short 2 0 = 80
1 = 128
2 = 256
3 = 384
4 = 512
5 = 640
6 = 768
7 = 896
8 = 1024
(Null to query in text)
ms
RINGON – Ring Cadence On Time
This command sets the ring cadence on time. The country code should be set first using the COUNTRY
command.
Command Form: DEVICE RINGON <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17 (R) -
Value Unsigned Short 2 0 = 100
1 = 150
2 = 200
3 = 256
4 = 384
5 = 512
6 = 640
7 = 1024
(Null to query in text)
ms
RXBOOST – Receive Boost
This command selects/reports the receive boost status.
Command Form: DEVICE RXBOOST <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17 (R) -
Value Unsigned Integer 2 0, 3, 6, 9, or 12
(Null to query in text)
dB
Page view 307
1 2 ... 303 304 305 306 307 308 309 310 311 312 313 ... 379 380

Comments to this Manuals