PAEQSET – PA EQ Filter Set
This command sets/reports the EQ Level for a given band in the filter bank
Command Form: DEVICE PAEQEN <Channel> <Group> <Band> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
-
Group Group 1 23 (J) -
Band Unsigned
Short
2 1 = 32.25 Hz
2 = 62.5 Hz
3 = 125.0 Hz
4 = 250.0 Hz
5 = 500.0 Hz
6 = 1000.0 Hz
7 = 2000.0 Hz
8 = 4000.0 Hz
9 = 8000.0 Hz
10 = 16000.0 Hz
Hz
Value Signed
Float
4 -12.00 – 12.00
(Null to query in text)
dB
PAFLT – PA Fault
This indicates one of the power amplifier channels is in a FAULT condition. This is Read-Only, and is
automatically generated if a fault occurs.
Command Form: DEVICE PAEQEN [Bitmap]
Argument Type Size Values
Bitmap Hexadecimal Integer 4
PAIMPED – PA Output Impedance
This command selects the output impedance for the PA channel to be either 8 ohms or 70/100V.
Command Form: DEVICE PIAMPED <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
-
Group Group 1 23 (J) -
Value Unsigned
Short
2 0 = 8 ohms
1 = 70/100V
(Null to query in text)
-
PALEN – PA Limiter Enable
This command changes enables the Limiter on a power amplifier channel.
Command Form: DEVICE PALEN <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 23 (J) -
Value Unsigned Short 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-