FILTSEL – Filter Select
This command turns on and off the filters.
Command Form: DEVICE FILTSEL <Channel> <Group> <Node> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3, 5, 23, 29 (M, P, J, V) -
Node Unsigned Integer 1 Group 3, 23, 29 1 – 4
0xFF for all (*
text)
-
Group 5 1 – 15
0xFF for all (*
text)
Value Unsigned Integer 1 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
FLOW – Flow Control
This command selects/reports the flow control of the serial port on the unit. Hardware flow control is implemented
using DTR and DSR.
Command Form: DEVICE FLOW [Value]
Argument Type Size Values Units
Value Unsigned Integer 4 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
FMP – First Mic Priority Mode
This command selects/reports first Mic priority mode.
Command Form: DEVICE FMP <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 4 (G) -
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
GAIN – Gain Adjustment
This command changes or reports back the gain for a channel.
Command Form: DEVICE GAIN <Channel> <Group> [Value] [Absol/Rel]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 1, 2, 3, 5, 7, 12, 16, 17, 25, 26 (I, J, O, M, P, L, F, T, R, K, Z,
D, U, V)
-
Value Signed
Float
2 -99.90 – 99.90 **
(Null to query in text)
dB
Absol / Rel 0 A = Absolute
R = Relative
Null = Relative
-
NOTE: Values indicate valid range for entry values only. Actual internal range of the gain stage
is from –65 to 20. Absolute values will be limited to the internal gain range.