Clearone Converge Pro User Manual Page 286

  • Download
  • Add to my manuals
  • Print
  • Page
    / 380
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 285
281
GATE – Gate Status
This command reports the gate status of Mics. This command is read only.
Command Form: DEVICE GATE [Value]
Argument Type Size Values Units
Value Hexadecimal 4 Bits 0 – 7 represent gate status on Mics 1 – 8
(Null sent in text, Value returned)
-
GHOLD – Gate Hold Time Adjust
This command selects/reports the setting of hold time.
Command Form: DEVICE GHOLD <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3 (M) -
Value Unsigned Float 2 0.10 – 8.00
(Null to query in text)
S
GMODE – Gating Mode
This command selects/reports the setting of gating mode.
Command Form: DEVICE GMODE <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3 (M) -
Value Unsigned Integer 2 1 = Auto
2 = Manual On
3 = Manual Off
(Null to query in text)
-
GOVER – Gating Override
This command selects/reports the setting of gating override.
Command Form: DEVICE GOVER <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3 (M) -
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
GPIOSTATUS – General Purpose Status
This command sets the state of a General Purpose Status Pin.
Command Form: DEVICE GPIOSTATUS Pin Port [Value]
Argument Type Size Values Units
Pin Unsigned
Integer
1 1 – 24 (Only user definable status pins.
-
Port Unsigned
Integer
1 1 – 2
-
Value Unsigned
Integer
2 0 = High
1 = Low
2 = Toggle
(NULL to query in text)
-