PUSHTOTALK – Push to Talk
This command selects/reports the setting of push-to-talk for a microphone.
Command Form: DEVICE PUSHTOTALK <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3 (M) -
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
RAMP – Ramp Gain Adjustment
This command starts / stops the gain ramp for an input, output or assignable processing block. There is no
query associated with this command.
Command Form: DEVICE RAMP <Channel> <Group> <Rate> [Target]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 1, 2, 3, 5, 7, 12, 16, 17, 25, 26 (I, J, O, M, P, L, F, T,
R, K, Z, D, U, V)
-
Rate Signed Integer 1 -50 – 50
If value=0, the ramp will stop.
If value< 0, the gain will ramp down.
If value>0, the gain will ramp up.
dB / s
Target Signed Integer 1 -65 – 20
If NULL in text or 0x80 in binary, the ramp will use
the channel’s maximum and minimum for a target.
dB
REDIAL – Redial the Last Number
This command redials the last number. There is no query for this command.
Command Form: DEVICE REDIAL <Channel>
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17 (R) -
Reserved 2 0 -
REFSEL – Reference Select for PA Adaptation & AEC
This command selects/reports which output or expansion bus reference is used for a Mic input as a reference for
power amp adaptation mode and acoustic echo cancellation where applicable.
Command Form: DEVICE REFSEL <Channel> [Ref. Group Ref. Channel]
Argument Type Size Values Units
Channel Channel 1 See 3 (M) in Groups and Channels -
Group Group 1 3 (M) -
Reference Group Group 1 2, 8, 20 (A, B, E, H, J, O) -
Reference Channel Channel 1 See Groups and Channels
(Null to query in text)
-
REFSET – Reference Channel Set Up
This command selects/reports the output the reference channel tracks.
Command Form: DEVICE REFSET <Channel> [Reference Output]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 20 (B) -
Value Reference Output 2 0 = none
See 2 (O) in Groups and Channels
(Null to query in text)
-