Gain Slider
The Gain slider adjusts the output gain level. To change the value, use the slider or selector box. Range is from -65
to +20dB in .5dB increments. The default is 0dB.
Min/Max Limits
Use the yellow and green upper and lower limit arrows on the Gain Scale in the Gain section of the screen to set
minimum and maximum gain level limits. These limits only apply when using relative gain commands; absolute gain
commands can exceed the min and max limits. Min/Max limits apply to all serially connected control devices and
prevent users from adjusting levels beyond the min/max levels.
Post-Gain Meter
The Post Gain level meter displays the post-gain signal level in dB.
Limiter
The Limiter limits the output level to the Telco side to comply with Telco system requirements. Note that the meter is
only a graphic; it does not show limiter activity. (Not used in VoIP settings)
Output Level Meter
Shows the signal level in dB when a signal is present.