258
DEVICESUBTYPE – Sets the Subtype of a Connected Device
This command enables/disables or reports the current type of device connected to an input or output.
Command Form: DEVICE DEVICESUBTYPE <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 1, 2, 3, 7 (I, O, M, L) -
Value Unsigned Integer 2 (NULL to query in text) -
DEVICETYPE – Sets the Type of a Connected Device
This command enables / disables or reports the current type of device connected to an input or output.
Command Form: DEVICE DEVICETYPE <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 1, 2, 3, 7 (I, O, M, L) -
Value Unsigned Integer 2 (NULL to query in text) -
DFLTM – Default Meter
This command selects/reports the setting of the default meter on the front panel.
Command Form: DEVICE DFLTM [Channel Group Position]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
(Null to query in text)
-
Group Group 1 1, 2, 3, 7, 16, 17 (I, O, M, L, T, R) -
Position Meter Type 2 1 – 4, as applicable for group
See Meter Type Definitions
-
DIAG – Diagnostic Commands
This command is used to return status and diagnostic information. It is intended to be used as a text command
only. This is a query only command.
Command Form: DEVICE DIAG <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 23 (J) -
Value Unsigned
Short
2 0 = List of current commands
(J) Power Amp
1 = Fan/Temp
2 = Noise Gate
3 = Feedback Nodes
-
Information String 80 Diagnostic String
(ALWAYS NULL IN TEXT)
-
DIAL – DTMF Dialing
This command dials a DTMF sequence or reports back the last sequence dialed.
Command Form: DEVICE DIAL <Channel> [Number]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17 (R) -
Reserved 2 0 -
Number String 40 1 – 40 Chars of ‘0’ – ‘9’, ‘*’, ‘#’, ‘,’
(Null to query last number dialed in text)
-