XAMBLVL – Ambient Level Adjust
This command selects/reports the ambient level. This command can be used to replace the AMBLVL command
for the M group.
Command Form: DEVICE XAMBLVL <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3, 29 (M, V) -
Value Signed Float 2 -80.00 – 0.00
(Null to query in text)
dB
XAARINGS – Number of Rings to Auto Answer On
This command selects/reports the setting of the number of rings to auto answer. This command can be used to
replace the AARINGS command for the R group.
Command Form: DEVICE XAARINGS <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17, 26 (R, Z) -
Value Unsigned Short 2 2-4
(Null to query in text)
-
XACONN – Audible Connect / Disconnect Indication
This command selects/reports the status of the audible connect / disconnect indication. This command can be
used to replace the ACONN command for the R group.
Command Form: DEVICE XACONN <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17, 26 (R, Z) -
Value Unsigned Short 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
XACONNLVL – Audible Connect / Disconnect Level
This command selects/reports the audible connect / disconnect indicator’s level. This command can be used to
replace the ACONNLVL command for the R group.
Command Form: DEVICE XACONNLVL <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 17, 26 (R, Z) -
Value Signed Short 2 -12.00 – 12.00
(Null to query in text)