ClearOne Converge Pro 840T Specifications Page 283

  • Download
  • Add to my manuals
  • Print
  • Page
    / 366
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 282
278
MTRXTYPE – Select Pre-AEC Gated or Non-Gated Routing
This command selects whether the Pre-AEC routing is Gated or Non-Gated.
Command Form:
DEVICE MTRXTYP <Type>
Argument Type Size Values Units
Type Integer 4 0 = Gated (Default)
1 = Non-Gated
2 = Toggle
(Null to query in text)
-
MUTE – Mute
This command selects/reports the setting of mute on a channel.
Command Form: DEVICE MUTE <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 1, 2, 3, 5, 7, 12, 16, 17, 25, 26 (I, J, O, M, P, L, F,
T, R, K, Z, D, U, V)
-
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
NAME – Unit Name (NETBIOS Name)
This command sets/reports the name of the unit which is also used for its NETBIOS name.
Command Form: DEVICE NAME [Value]
Argument Type Size Values Units
Value String 16 1 – 15 Characters
(Null to query in text)
-
NCD – Noise Cancellation Depth Adjust
This command selects/reports the depth setting of the Noise Cancellation.
Command Form: DEVICE NCD <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3, 17, 26 (M, R, Z, V) -
Value Unsigned Integer 2 6 – 15
(Null to query in text)
dB
NCSEL – Noise Cancellation Select
This command selects/reports the setting of the Noise Cancellation for each microphone channel.
Command Form: DEVICE NCSEL <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3, 17, 26 (M, R, Z, V) -
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
Page view 282
1 2 ... 278 279 280 281 282 283 284 285 286 287 288 ... 365 366