XCOMPRESS – Compressor Adjust
This command controls/reports the signal compression setting on a Channel. This command can be used to
replace the COMPRESS command for the P group.
Command Form: DEVICE XCOMPRESS <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 23 (J, P) -
Value Unsigned Short 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
XCOMPSEL – Compressor Enable
This command enables signal compression on a Channel. This command can be used to replace the COMPSEL
command for the P group.
Command Form: DEVICE XCOMPSEL <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 23 (J, P) -
Value Unsigned Short 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
XDECAY – Decay Adjust
This command selects/reports the setting of the decay rate. This command can be used to replace the DECAY
command for the M group.
Command Form: DEVICE XDECAY <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 3, 29 (M, V) -
Value Unsigned Short 2 1 = Slow
2 = Medium
3 = Fast
(Null to query in text)
-
XDELAY – Audio Delay
This command controls/reports signal delay on a Channel. This command can be used to replace the DELAY
command for the P group.
Command Form: DEVICE XDELAY <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels -
Group Group 1 5, 23 (P, J) -
Value Unsigned Short 2 0.0 – 250.00
(Null to query in text)
ms